Thermal imaging camera C.A 1954

  • exceptional 9-hour battery life with standard Ni-MH rechargeable batteries or alkaline batteries connectivity with current clamps and environmental measurement products
  • all the necessary measurements simultaneously (current, influencing quantities, dew point for identifying areas at risk from mold, etc.)
  • voice annotations to record your comments directly on the image 
  • the possibility of renaming the images and thermograms by site recording and storage in memory of the configurations for each application.
Manufacturer:
CHAUVIN ARNOUX

Description

Designed and developed for simplified use, the C.A 1954 is ideal for all applications in the building, electrical maintenance and mechanical maintenance for 

  • thermal audits fault detection: thermal bridges, seepage, presence of humidity;
  • electrical maintenance: detection of faulty contacts, unbalance, etc.;
  • mechanical maintenance: detection of wear points, motor overheating, lubrication problems, etc. 

It has been specially designed to be simple to use:

  • comfortable grip, with direct access to the functions;
  • with just one hand the C.A 1954 is perfectly balanced and does not move even when stood on a table or bench display on a wide 2.8-inch screen;
  • with automatic brightness adjustment, the field of view (38°x28°) is focus-free, which means that the image remains sharp whatever the distance;
  • contextual help guides users to limit the risk of errors;
  • the C.A 1954 allows you to record voice comments directly on the image;
  • the slide-down protective lens cover is built into the instrument, so you cannot lose it and it does not get in the way.
Attribute NameAttribute Value
Documentation from Manufacturer
Type
UFPA microbolometer
Laser Class
2
Resolution (px)
120 x 160
Spectral Sensitivity
14 um
Frame/Line/Measuring/Response Rate/Frequency (Hz)
9
Wavelength/Measuring Beam (nm)
655 nm
Accuracy
±2 °C, ±2 %
Interface
USB, Bluetooth
Connection
Cable, Over the Air
Special Requirements
Resistance to vibrations
Weight (g)
700 g
Protection Rating Housing
IP54
Approval
IEC, CE
Housing Material
Not specified

Contact

Address

Sweden, Solna, Signalistgatan 14, 16972.

Follow Us